Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
J Arrhythm ; 40(2): 363-373, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586857

RESUMO

Background: The precise details of atrial activation around the triangle of Koch (ToK) remain unknown. We evaluated the relationship between the atrial-activation pattern around the ToK and success sites for slow-pathway (SP) modification ablation in slow-fast atrioventricular reentrant tachycardia (AVNRT). Methods: Thirty patients with slow-fast AVNRT who underwent successful ablation were enrolled. Atrial activation around the ToK during sinus rhythm was investigated using ultra-high-density mapping pre-ablation. The relationships among features of atrial-activation pattern and success sites were examined. Results: Of 30 patients (22 cryoablation; 8 radiofrequency ablation), 26 patients had a collision site of two wavefronts of delayed atrial activation within ToK, indicating a success site. The activation-search function of Lumipoint software, which highlights only atrial activation with a spatiotemporal consistency, showed non-highlighted area on the tricuspid-annulus side of ToK. In 23 of the patients, a spiky potential was recorded at that collision site outside the Lumipoint-highlighted area. Fifteen cryoablation patients with a success site coincident with a collision site outside the Lumipoint-highlighted area had significantly more frequent disappearances of SP after initial cryoablation (46.7% vs. 0%, p = .029), fewer cryoablations (3.7 ± 1.8 vs. 5.3 ± 1.3, p = .045), and shorter procedure times (170 ± 57 vs. 228 ± 91 min, p = .082) compared to the seven cryoablation patients without such sites. Four patients had transient AV block by ablation inside the Lumipoint-highlighted area with fractionated signals, but no patient developed permanent AV block or recurrence post-procedure (median follow-up: 375 days). Conclusions: SP modification ablation at the collision site of atrial activation of the tricuspid-annulus side along with a spiky potential could provide a better outcome.

2.
Hypertens Res ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532036

RESUMO

Lack of the typical nocturnal blood pressure (BP) fall, i.e non-dipper, has been known as a cardiovascular risk. However, the influence of non-dipper on atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been unclear. We investigated the clinical impact of non-dipping as evaluated by 24-hour ambulatory BP monitoring on the long-term outcome of AF recurrence post-PVI in 76 AF patients with a history of increased BP. The PVI procedure was successful in all 76 patients (mean age, 66±9years; antihypertensive medication, 89%; non-paroxysmal AF, 24%). Twenty patients had AF recurrence during a median follow-up of 1138 days. There was no difference in BP levels between the AF recurrence and non-recurrence groups (average 24 h systolic BP:126 ± 17 vs.125 ± 14 mmHg; P = 0.84). On the other hand, the patients with non-dipper had a higher AF recurrence than those with dipper (38.9% vs.15.0%; P = 0.018). In Cox hazard analysis adjusted by age, non-paroxysmal AF and average 24-hr systolic BP level, the non-dipper was an independent predictor of AF recurrence (HR 2.78 [95%CI:1.05-7.34], P = 0.039). Non-dipper patients had a larger left atrial (LA) volume index than the dipper patients (45.9 ± 17.3 vs.38.3 ± 10.2 ml/m2, P = 0.037). Among the 58 patients who underwent high-density voltage mapping in LA, 11 patients had a low-voltage area (LVA) defined as an area with a bipolar voltage < 0.5 mV. However, there was no association of LVA with non-dipper or dipper (22.2% vs.16.1%, P = 0.555). Non-dipper is an independent predictor of AF recurrence post-PVI. Management of abnormal diurnal BP variation post-PVI may be important.

3.
Mediastinum ; 8: 1, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322191

RESUMO

Cardiovascular implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter defibrillators require the placement of a transvenous lead through the superior vena cava (SVC), which can be difficult if there is stenosis or obstruction of the SVC. Moreover, SVC syndrome may occur after the lead is inserted even if the SVC was intact before the implantation. Therefore, there is need of an appropriate strategy for handling stenosis or obstruction of SVC during lead placement. In addition, advances are being made in CIEDs that do not require transvenous leads, and thus CIEDs without a transvenous lead should be considered depending on the indications and urgency of the particular case. This manuscript is divided into (I) device therapy for patients with SVC obstruction and (II) therapeutic strategy for SVC obstruction after lead implantation. In patients with SVC syndrome, treatment of the SVC occlusion should be based on the individual pathophysiology, and depending on the indications and urgency of the case, treatment with CIEDs that do not require transvenous leads should be considered. Further data must be accumulated to clarify the long-term prognosis of device implantation after treatment of SVC occlusion. In addition, transvenous lead extraction is now widely used for device-related SVC obstruction, and this procedure also merits further accumulation of data.

4.
J Arrhythm ; 40(1): 30-37, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333398

RESUMO

Background: Temporal change in outcomes of heart failure patients receiving cardiac resynchronization therapy with a defibrillator (CRT-D) is unknown. Methods: We assess outcomes and underlying heart diseases of patients receiving CRT-D with analyzing database of the Japan cardiac device treatment registry (JCDTR) at the implantation year 2011-2015 and New JCDTR at the implantation year 2018-2021. Results: Proportion of nonischemic heart diseases was about 70% in both the groups (JCDTR: 69%; New JCDTR: 72%). Cardiac sarcoidosis increased with the rate of 5% in the JCDTR to 9% in the New JCDTR group. During an average follow-up of 21 months, death from any cause occurred in 167 of 906 patients in the JCDTR group (18%) and 79 of 611 patients in the New JCDTR group (13%) (adjusted hazard ratio [aHR] in the New JCDTR group, 0.72; 95% confidence interval [CI]: 0.55-0.94; p = .017). The superiority was mainly driven by reduction in the risk of noncardiac death. With regard to appropriate and inappropriate implantable cardioverter-defibrillator (ICD) therapy, there was a significant reduction in the New JCDTR group versus the JCDTR group (aHR in the New JCDTR group, 0.76; 95% CI: 0.59-0.98; p = .032 for appropriate ICD therapy; aHR in the New JCDTR group, 0.24; 95% CI: 0.12-0.50; p < .0001 for inappropriate ICD therapy). Conclusions: All-cause mortality was reduced in CRT-D patients implanted during 2018-2021 compared to those during 2011-2015, with a significant reduction in noncardiac death.

5.
Hypertens Res ; 47(2): 507-514, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37903956

RESUMO

Several studies investigated the association between nighttime blood pressure (BP) and left ventricular hypertrophy (LVH) in diabetes, but since most of these studies were conducted in diabetes populations only, they did not compare differences in the impact of nighttime BP on LVH in subjects without diabetes. Moreover, data about the impact of glucose control in diabetes on the relationship between nighttime BP and LVH are sparse. We classified 1277 adults (age 64.7 ± 11.8 years) performing ambulatory BP monitoring while enrolled as part of the Japan Morning Surge Home Blood Pressure (J-HOP) study into groups according to the control status of daytime BP (systolic BP [SBP] < 135 mmHg or ≥135 mmHg), nighttime BP (SBP < 120 mmHg or ≥120 mmHg), and diabetes (HbA1c < 7.0% or ≥7.0%). LVH was assessed by echocardiography. LVH according to echocardiographic criteria was identified in 33.7% of the participants. The group with poorly controlled diabetes plus uncontrolled nighttime BP (n = 90) had a 2.1-fold higher risk of LVH compared to the group with controlled nighttime BP and non-diabetes (n = 505) (odds ratio [OR] 2.10, 95% confidence interval [CI]: 1.29-3.44). No association was observed between uncontrolled daytime BP and diabetes for LVH. In the participants with poorly controlled diabetes (n = 146), uncontrolled nighttime BP posed a 3.1-fold higher risk of LVH compared to controlled nighttime BP (OR 3.12, 95%CI: 1.47-6.62). This association was not found in controlled diabetes. Uncontrolled nighttime BP was associated with a risk of LVH, especially among individuals with poorly controlled diabetes.


Assuntos
Diabetes Mellitus , Hipertensão , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Pressão Sanguínea/fisiologia , Hipertrofia Ventricular Esquerda/complicações , Hipertensão/complicações , Glicemia , Japão , Monitorização Ambulatorial da Pressão Arterial
8.
J Am Heart Assoc ; 12(23): e030992, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38038188

RESUMO

BACKGROUND: Blood pressure (BP) thresholds for diagnosing and managing hypertension vary for office, home, and ambulatory readings, and between guideline documents. This analysis determined corresponding office, home, and ambulatory BP thresholds using baseline data from the HI-JAMP (Home-Activity Information and Communication Technology-Based Japan Ambulatory Blood Pressure Monitoring Prospective) study, which used a validated "all-in-one" BP monitoring device. METHODS AND RESULTS: Data from 2322 treated patients with hypertension who underwent office BP measurement, then 24-hour ambulatory BP monitoring, then home BP monitoring for 5 days were analyzed. Corresponding BP thresholds for office, home, and ambulatory measurements were determined using Deming regression. Values equivalent to office systolic BP (SBP) of 120 and 140 mm Hg were as follows: 115.9 and 127.7 mm Hg for 24-hour ambulatory SBP; 120.8 and 134.0 mm Hg for daytime ambulatory SBP; 104.9 and 117.9 mm Hg for nighttime ambulatory SBP; and 122.0 and 134.2 mm Hg for morning-evening average home SBP. Deming regression showed that morning-evening average home SBP and daytime ambulatory SBP were almost the same (home SBP=0.99×daytime ambulatory SBP+0.27 mm Hg; r=0.627). Morning-evening average home SBP values of 120 and 135 mm Hg were equivalent to daytime ambulatory SBP values of 119.1 and 133.9 mm Hg, respectively. A home SBP threshold of 130 mm Hg corresponded to 24-hour and nighttime ambulatory SBP values of 123.5 and 113.6 mm Hg, whereas a home SBP threshold of 135 mm Hg corresponded to 24-hour and nighttime ambulatory SBP values of 128.0 and 119.2 mm Hg. CONCLUSIONS: Ambulatory and home BP thresholds in this analysis were similar to those proposed by existing guidelines. The similarity between the home BP and daytime ambulatory BP thresholds was a clinically relevant finding.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Estudos Prospectivos , Hipertensão/diagnóstico , Determinação da Pressão Arterial
9.
Open Heart ; 10(2)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38065584

RESUMO

OBJECTIVE: This study aimed to investigate the association between heart failure (HF) severity measured based on brain natriuretic peptide (BNP) levels and future bleeding events after percutaneous coronary intervention (PCI). BACKGROUND: The Academic Research Consortium for High Bleeding Risk presents a bleeding risk assessment for antithrombotic therapy in patients after PCI. HF is a risk factor for bleeding in Japanese patients. METHODS: Using an electronic medical record-based database with seven tertiary hospitals in Japan, this retrospective study included 7160 patients who underwent PCI between April 2014 and March 2020 and who completed a 3-year follow-up and were divided into three groups: no HF, HF with high BNP level and HF with low BNP level. The primary outcome was bleeding events according to the Global Use of Streptokinase and t-PA for Occluded Coronary Arteries classification of moderate and severe bleeding. The secondary outcome was major adverse cardiovascular events (MACE). Furthermore, thrombogenicity was measured using the Total Thrombus-Formation Analysis System (T-TAS) in 536 consecutive patients undergoing PCI between August 2013 and March 2017 at Kumamoto University Hospital. RESULTS: Multivariate Cox regression showed that HF with high BNP level was significantly associated with bleeding events, MACE and all-cause death. In the T-TAS measurement, the thrombogenicity was lower in patients with HF with high BNP levels than in those without HF and with HF with low BNP levels. CONCLUSIONS: HF with high BNP level is associated with future bleeding events, suggesting that bleeding risk might differ depending on HF severity.


Assuntos
Insuficiência Cardíaca , Peptídeo Natriurético Encefálico , Intervenção Coronária Percutânea , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química
10.
J Arrhythm ; 39(5): 757-765, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799798

RESUMO

Background: Panoramic studies in patients with cardiac resynchronization therapy with a defibrillator (CRT-D) focusing on the etiology and indication are scarce. Besides, a controversy exists regarding requirement of a defibrillator in non-ischemic patients for primary prevention with CRT. Methods: Annual trends of de novo CRT-D implantations from 2011 to 2020 and outcomes of those between January 2011 and August 2015 were analyzed from the Japan cardiac device treatment registry (JCDTR) and New JCDTR database. Results: From 2011 to 2020, 8062 CRT-D recipients were registered, whose dominant indication was primary prevention of sudden cardiac death with a steady rate of about 70%. There was no significant temporal change of the proportion of non-ischemic patients being about 70% and 65% for primary and secondary prevention, respectively. Non-ischemic patients for primary prevention were associated with increased odds of appropriate ICD therapy [adjusted hazard ratio (aHR): 1.66; 95% confidence interval (CI): 1.01-2.75; p = .047] and reduced odds of any death (aHR: 0.66; 95% CI: 0.44-0.99; p = .046) as compared to ischemic patients. Conclusions: Proportion of non-ischemic etiology was much higher than that of ischemic one in the CRT-D cohort. Based on the higher odds of appropriate ICD therapy, non-ischemic patients for primary prevention appear to be prudently selected in Japan.

11.
Hypertension ; 80(11): 2464-2472, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37671575

RESUMO

BACKGROUND: Home blood pressure (BP) is an important component of digital strategies for hypertension management. However, no studies have used the same device to investigate 24-hour BP control status in relation to different home BP control thresholds. METHODS: Participants in the general practitioner-based, multicenter HI-JAMP study (Home-Activity Information and Communication Technology-Based Japan Ambulatory Blood Pressure Monitoring Prospective) underwent office BP measurement, then 24-hour ambulatory BP monitoring, then home BP monitoring for 5 days. A validated all-in-one BP monitoring device was used to measure office, home, and ambulatory BP. Baseline data were used to investigate ambulatory BP control status in individuals with well-controlled home BP based on the different guideline thresholds (125/75 mm Hg, 130/80 mm Hg, and 135/85 mm Hg). RESULTS: Data from 2269 patients were analyzed. For individuals with well-controlled home BP <135/85 mm Hg (59.5% of the total population), the prevalence of uncontrolled 24-hour (≥130/80 mm Hg), daytime (≥135/85 mm Hg), and nighttime ambulatory BP (≥120/70 mm Hg) was 19.9%, 18.5%, and 33.6%, respectively. Corresponding prevalence rates in the 42.7% of participants with well-controlled home BP <130/80 mm Hg were 13.4%, 12.9%, and 26.0%, and when well-controlled home BP was strictly defined as <125/75 mm Hg (23.9% of the population), prevalence of rates of uncontrolled 24-hour, daytime, and nighttime ambulatory BP were 7.0%, 9.0%, and 15.3%, respectively. CONCLUSIONS: Home BP control status defined using different thresholds could predict 24-hour ambulatory BP control status in treated hypertension. One-third of individuals still had uncontrolled nocturnal hypertension when home BP was controlled to <135/85 mm Hg, but ambulatory BP was quite well controlled when home BP was <125/75 mm Hg.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/epidemiologia , Estudos Prospectivos
12.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37539865

RESUMO

AIMS: The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. METHODS AND RESULTS: Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). CONCLUSION: Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Apêndice Atrial/cirurgia , Taquicardia/etiologia , Tomografia Computadorizada por Raios X , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Arrhythm ; 39(4): 574-579, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37560274

RESUMO

Background: While most VVI pacemakers in bradycardic patients are set to a low limit of 60/min, the optimal lower limit rate for VVI pacemakers in atrial fibrillation has not been established. Although an increase in heart rate within the normal range in the setting of a VVI pacemaker might be expected to lead to an increase in cardiac output with the shortening of the diastolic time, the changes in cardiac output at different pacemaker settings have not been fully clarified. Methods: We included 11 patients with bradycardic atrial fibrillation who had VVI pacemakers implanted. Stroke volume was measured using the electrical cardiometry method (AESCULONⓇ mini; Osypka Medical) without pacing and at ventricular pacings of 60, 70, 80, and 90/min. Results: Stroke volume decreased stepwise at ventricular pacing rates of 60, 70, 80, and 90/min (63.6 ± 11.2, 61.9 ± 10.6, 59.3 ± 12.2, and 57.5 ± 12.2 mL, p < .001), but cardiac output increased (3.81 ± 0.67, 4.33 ± 0.74, 4.74 ± 0.97, and 5.17 ± 1.09 L/min, p < .001). The rate of increase in cardiac output at a pacing rate of 70/min compared to 60/min correlated with left ventricular end-systolic volume (r = 0.711, p = .014). Conclusions: Cardiac output increased at a pacing rate of 70 compared to 60 in bradycardic atrial fibrillation patients, and the rate of increase in cardiac output was greater in those with larger left ventricular end-systolic volume.

14.
Int J Cardiol Cardiovasc Risk Prev ; 18: 200193, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37415925

RESUMO

Background: Heart failure (HF) is associated with a high bleeding risk after percutaneous coronary intervention (PCI). Additionally, major bleeding events increase the risk of subsequent major adverse cardiac events (MACE). However, whether brain natriuretic peptide (BNP) levels and major bleeding events following PCI are associated with MACE and all-cause death remains unknown. This study aimed to investigate the impact of HF severity or bleeding on subsequent MACE and all-cause death. Methods: The Clinical Deep Data Accumulation System (CLIDAS), a multicenter database involving seven hospitals in Japan, was developed to collect data from electronic medical records. This retrospective analysis included 7160 patients who underwent PCI between April 2014 and March 2020 and completed a three-year follow-up. Patients were divided according to the presence of HF with high BNP (HFhBNP) (>100 pg/ml) and major bleeding events within 30 days post-PCI (30-day bleeding): HFhBNP with bleeding (n = 14), HFhBNP without bleeding (n = 370), non-HFhBNP with bleeding (n = 74), and non-HFhBNP without bleeding (n = 6702). Results: In patients without 30-day bleeding, HFhBNP was a risk factor for MACE (hazard ratio, 2.19; 95% confidence interval, 1.56-3.07) and all-cause death (hazard ratio, 1.60; 95% confidence interval, 1.60-2.23). Among HFhBNP patients, MACE incidence was higher in patients with 30-day bleeding than in those without bleeding, but the difference was not significant (p = 0.075). The incidence of all-cause death was higher in patients with bleeding (p = 0.001). Conclusions: HF with high BNP and bleeding events in the early stage after PCI might be associated with subsequent MACE and all-cause death.

15.
J Cardiovasc Electrophysiol ; 34(4): 849-859, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738145

RESUMO

INTRODUCTION: Beyond pulmonary vein isolation (PVI), additional therapeutic strategies for atrial fibrillation (AF) have not been established. Remodeling of the left atrium (LA) could impact AF recurrence post-PVI. We investigated the impact of unipolar voltage (UV) criteria for the LA posterior wall (LA-PW) on AF recurrence post-PVI. METHODS: We reviewed the cases of 106 AF patients (mean age 63.8 years, nonparoxysmal AF: 59%) who underwent extensive encircling PVI by radiofrequency ablation guided by a 3-dimension mapping system, investigating the impact on AF recurrence of the UV criteria of the LA. RESULTS: Out of all patients, 26 patients had AF recurrence during post-PVI follow-up [median 603 days]. They showed a higher percentage of nonparoxysmal AF (80.8 vs. 52.5%, p = .011), longer AF duration (2.9 ± 2.7 vs. 1.0 ± 1.7 years, p = .002), and larger area size of UV < 2.0 mV in LA-PW (2.8 ± 1.8 vs. 1.0 ± 1.5 cm2 , p < .001) than those without recurrence. Cox Hazard analysis for AF recurrence adjusted by age, gender, AF duration, body mass index and left atrial volume index revealed that an area size over 2.0 cm2 of UV < 2.0 mV in LA-PW (HR 6.9 [95% CI:1.3-35.5], p = .021) posed independent risks for AF recurrence post-PVI. The atrial arrhythmia-free survival rate was higher in those with no area of UV < 3.0 mV in LA-PW compared to those with a sizable area (>2.0 cm2 ) of UV < 3.0 mV and <2.0 mV (95.0% vs. 74.2% vs. 57.1%, Log-Rank: p < .001). In the AF etiology of patients with AF recurrence, 9 of 14 patients who underwent the 2nd procedure had no PV reconnection, and 8 patients required the LA-PW isolation for their non-PV AF. CONCLUSION: UV criteria of LA-PW is a useful parameter for AF-recurrence post-PVI. Lower UV in LA-PW as an indication of electrical remodeling could indicate a higher risk of AF recurrence and the need for further therapeutic strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
16.
Intern Med ; 62(8): 1191-1194, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36754404

RESUMO

A 23-year-old man with no significant medical history was rushed to a hospital due to transient loss of consciousness with incontinence. The patient had developed a fever after his second dose of coronavirus disease 2019 (COVID-19) vaccine, and the patient was found groaning in bed approximately 40 hours after the vaccination in the early morning. The patient was diagnosed with Brugada syndrome (BrS) based on a drug-provocation test. His father had been diagnosed with BrS and died suddenly at 51 years of age. Young adults with a family history of BrS should be cautioned about fever following COVID-19 vaccination.


Assuntos
Síndrome de Brugada , Vacinas contra COVID-19 , COVID-19 , Adulto , Humanos , Masculino , Adulto Jovem , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/etiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Eletrocardiografia , Febre , Síncope/etiologia
17.
Circ J ; 87(6): 775-782, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36709982

RESUMO

BACKGROUND: Several studies have reported some sex differences in patients with coronary artery diseases. However, the results regarding long-term outcomes in patients with chronic coronary syndrome (CCS) are inconsistent. Therefore, the present study investigated sex differences in long-term outcomes in patients with CCS after percutaneous coronary intervention (PCI).Methods and Results: This was a retrospective, multicenter cohort study. We enrolled patients with CCS who underwent PCI between April 2013 and March 2019 using the Clinical Deep Data Accumulation System (CLIDAS) database. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, or hospitalization for heart failure. In all, 5,555 patients with CCS after PCI were included in the analysis (4,354 (78.4%) men, 1,201 (21.6%) women). The median follow-up duration was 917 days (interquartile range 312-1,508 days). The incidence of MACE was not significantly different between the 2 groups (hazard ratio [HR] 1.20; 95% confidential interval [CI] 0.97-1.47; log-rank P=0.087). After performing multivariable Cox regression analyses on 4 different models, there were still no differences in the incidence of MACE between women and men. CONCLUSIONS: There were no significant sex differences in MACE in patients with CCS who underwent PCI and underwent multidisciplinary treatments.


Assuntos
Doença das Coronárias , Intervenção Coronária Percutânea , Feminino , Humanos , Masculino , Estudos de Coortes , População do Leste Asiático , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Fatores Sexuais , Doença das Coronárias/epidemiologia
18.
Clin Res Cardiol ; 112(1): 98-110, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35760927

RESUMO

BACKGROUND: Non-dipper and riser patterns of nocturnal blood pressure (BP) are risk factors for cardiovascular disease (CVD), including heart failure (HF). However, the risk associated with a disrupted nocturnal pattern of heart rate is not well known. OBJECTIVES: To investigate whether the nighttime heart rate is a risk factor for HF, alongside nighttime BP phenotype. METHODS: The practitioner-based, nationwide, prospective Japan Ambulatory Blood Pressure Monitoring Prospective (JAMP) study included patients with ≥ 1 CVD risk factor but without symptomatic CVD at baseline. All patients underwent 24-h ambulatory BP monitoring at baseline and were followed annually. Nocturnal heart rate dipping (%) was calculated as 100•[1 - nighttime/daytime heart rate]. RESULTS: During a mean 4.5 years' follow-up in 6,359 patients (mean age 68.6 years), there were 306 CVD events (119 stroke, 99 coronary artery disease, and 88 HF). A 10-beats/min increase in nighttime heart rate was significantly associated with a 36-47% increase in the risk of total CVD, stroke and HF events independently of office SBP and nighttime SBP (all p < 0.005). The CVD and HF risk associated with nocturnal heart rate dipping status was independent of office and 24-h systolic BP and nocturnal BP dipping status (p < 0.001). Performance of the final model for predicting HF including BP parameters was significantly improved by the addition of nocturnal heart rate dipping patterns (p = 0.038; C-statistic 0.852). CONCLUSION: Nighttime non-dipper and riser patterns of heart rate were associated with CVD especially HF, independently and additively of nocturnal BP dipping status, indicating the importance of antihypertensive strategies targeting nighttime hemodynamics. CLINICAL TRIAL REGISTRATION: URL: https://www.umin.ac.jp/ctr/ ; Unique identifier: UMIN000020377.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/complicações , Ritmo Circadiano/fisiologia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/complicações , Hipertensão/complicações , Hipertensão/epidemiologia , Japão/epidemiologia , Estudos Prospectivos , Fatores de Risco , Idoso
19.
Am J Hypertens ; 36(2): 90-101, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36053278

RESUMO

BACKGROUND: Inconsistencies between the office and out-of-office blood pressure (BP) values (described as white-coat hypertension or masked hypertension) may be attributable in part to differences in the BP monitoring devices used. METHODS: We studied consistency in the classification of BP control (well-controlled BP vs. uncontrolled BP) among office, home, and ambulatory BPs by using a validated "all-in-one" BP monitoring device. In the nationwide, general practitioner-based multicenter HI-JAMP study, 2,322 hypertensive patients treated with antihypertensive drugs underwent office BP measurements and 24-hour ambulatory BP monitoring (ABPM), consecutively followed by 5-day home BP monitoring (HBPM), for a total of seven BP measurement days. RESULTS: Using the thresholds of the JSH2019 and ESC2018 guidelines, the patients with consistent classification of well-controlled status in the office (<140 mmHg) and home systolic BP (SBP) (<135 mmHg) (n = 970) also tended to have well-controlled 24-hour SBP (<130 mmHg) (n = 808, 83.3%). The patients with the consistent classification of uncontrolled status in office and home SBP (n = 579) also tended to have uncontrolled 24-hour SBP (n = 444, 80.9%). Among the patients with inconsistent classifications of office and home BP control (n = 803), 46.1% had inconsistent ABPM-vs.-HBPM out-of-office BP control status. When the 2017 ACC/AHA thresholds were applied as an alternative, the results were essentially the same. CONCLUSIONS: The combined assessment of the office and home BP is useful in clinical practice. Especially for patients whose office BP classification and home BP classification conflict, the complementary clinical use of both HBPM and ABPM might be recommended.


Assuntos
Hipertensão , Hipertensão do Jaleco Branco , Humanos , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Determinação da Pressão Arterial/métodos , Hipertensão do Jaleco Branco/diagnóstico
20.
Circ J ; 87(2): 336-344, 2023 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-36216562

RESUMO

BACKGROUND: The optimal heart rate (HR) and optimal dose of ß-blockers (BBs) in patients with coronary artery disease (CAD) have been unclear. We sought to clarify the relationships among HR, BB dose, and prognosis in patients with CAD using a multimodal data acquisition system.Methods and Results: We evaluated the data for 8,744 CAD patients who underwent cardiac catheterization from 6 university hospitals and the National Cerebral and Cardiovascular Center and who were registered using the Clinical Deep Data Accumulation System. Patients were divided into quartile groups based on their HR at discharge: Q1 (HR <60 beats/min), Q2 (HR 60-66 beats/min), Q3 (HR 67-74 beats/min), and Q4 (HR ≥75 beats/min). Among patients with acute coronary syndrome (ACS) and patients with chronic coronary syndrome (CCS), those in Q4 (HR ≥75 beats/min) had a significantly greater incidence of major adverse cardiac and cerebral events (MACCE) compared with those in Q1 (ACS patients: hazard ratio 1.65, P=0.001; CCS patients: hazard ratio 1.45, P=0.019). Regarding the use of BBs (n=4,964), low-dose administration was significantly associated with MACCE in the ACS group (hazard ratio 1.41, P=0.012), but not in patients with CCS after adjustment for covariates. CONCLUSIONS: HR ≥75 beats/min was associated with worse outcomes in patients with CCS or ACS.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/tratamento farmacológico , Frequência Cardíaca/fisiologia , Prognóstico , Antagonistas Adrenérgicos beta/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...